Product Details
Data Sheet | Download Datasheet |
---|---|
Usually Ships Within | Same Day |
Factory Stock | 15 |
Factory Location | Bowling Green, Ohio |
O Ring Seals | Buna |
Voltage | None |
Country of Manufacture | Germany |
Height | 1.85 |
Length | 1.85 |
Width | 1.85 |
Weight | 0.15 |
Description
Filter elements installed in hydraulic filters remove dirt from a hydraulic system and therefore become contaminated themselves. Free pores or spaces in the filter material are obstructed by dirt particles, which causes a continuous increase in the pressure loss. The dirt load collected in a filter element gradually increases during service, which also leads to a higher pressure drop. The resulting differential pressure Delta P is monitored by a clogging indicator. Once a preset value is reached, an electrical and or optical signal is generated. The following must be observed in this context - The pressure drop caused by the filter element increases depending on the flow rate, the dirt load, and the viscosity of the pressure fluid. Therefore, a filter element is not regarded contaminated before the clogging indicator responds at operating temperature of the hydraulic system, causing a continuous signal. This gauge is a manometer for optical monitoring of the dirt load in return filters.
- Opens in a new window.